DNS-323에서 하드디스크 SMART 정보 보기
SMART 정보를 보여 주는 smartmontools를 설치하려면, 먼저 ffp를 설치해야 한다. (참고: DNS-323에 텔넷 설치하기) 텔넷에 접속하여 다음과 같은 명령으로 적당한 자료방에 smartmontools를 받는다.
# cd /mnt/HD_a2/packages (또는 적당한 임시 자료방)
# wget http://www.inreto.de/dns323/fun-plug/0.5/packages/smartmontools-5.39.1-1.tgz
받은 파일을 설치한다.
# funpkg -i smartmontools-5.39-1-1.tgz
SMART 보고를 할 수 있게 한다.
# smartctl -i -d marvell /dev/sda
# smartctl -i -d marvell /dev/sdb
다음 명령으로 아래와 같은 SMART 정보를 볼 수 있다.
# smartctl -a -i -d marvell /dev/sda
# smartctl -a -i -d marvell /dev/sdb
smartctl 5.39.1 2010-01-28 r3054 [arm-unknown-linux-uclibc] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net=== START OF INFORMATION SECTION ===
Device Model: WDC WD20EARS-00MVWB0
Serial Number: WD-WCAZA0150453
Firmware Version: 50.0AB50
User Capacity: 2,000,398,934,016 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Wed Sep 1 17:04:21 2010 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSEDGeneral SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command
from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (37800) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off supp
ort.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 255) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x3035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_
FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always -
0
3 Spin_Up_Time 0x0027 171 168 021 Pre-fail Always -
6425
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always -
87
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always -
0
7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always -
0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always -
370
10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always -
0
11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always -
0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always -
13
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always -
11
193 Load_Cycle_Count 0x0032 199 199 000 Old_age Always -
4515
194 Temperature_Celsius 0x0022 109 107 000 Old_age Always -
41
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always -
0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always -
0
198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline -
0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always -
0
200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline -
0SMART Error Log Version: 1
No Errors LoggedSMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
덧글을 달아 주세요